From automated microscopy to retinal imaging, microscopIA brings engineering and clinical expertise together to study tools that could expand access to specialist capacity.
Research collaboration requires agreed scientific contributions and responsibilities. Paid scientific services are quoted by scope and deliverables. Technology development and validation require specific plans, permissions and evaluation criteria; neither implies regulatory authorization.
Send a nonconfidential brief. We review feasibility, disciplines, timing and budget before agreeing the project.
This evidence family documents concepts, physical prototypes, task-specific development benchmarks, validation gaps and human decision boundaries. microscopIA develops technology for settings where specialist capacity is limited without presenting investigational systems as clinical products.
CAD concept walkthroughSilent 45-second rotation of an early investigational CAD enclosure and base. It does not demonstrate clinical performance or an approved medical device.
microscopIA-led device–AI program · research stage
Retinal-imaging and referral-support research for preterm infants
microscopIA is developing an integrated research system for retinal imaging in preterm infants. The device is intended to support a high-resolution camera, primarily a compatible smartphone, to improve inspection and capture of infant retinal images.
Research models analyze de-identified retinal images to study image quality and features of retinopathy of prematurity (ROP). The intended goal is to help identify infants with concerning findings or higher risk for referral to a ROP-trained ophthalmologist, who retains diagnosis and treatment decisions. Future use is being evaluated for appropriately trained neonatologists, neonatal nurses and physicians, including general practitioners where permitted, working under approved institutional protocols and local scope-of-practice rules.
Human-led research pathway
Existing eligibility and follow-up protocol
Image acquisition by a trained professional
Image-quality check and research AI analysis
Qualified clinical review
Established specialist referral and follow-up
Ungradable image or failed acquisition → repeat or escalate under the approved protocol. There is no AI-created ‘no referral’ pathway.
Task-specific development benchmarks—not clinical performance.
Source last modified 19 November 2025. Values are shown by model task because the supplied record does not establish performance of an integrated device–AI system.
93.10%Accuracy · reported scoreResNet50 · public development dataset
Vessel segmentation
76.81%Intersection over UnionU-Net · HVDROPDB
How should I interpret these results?
These are early model-development measures, not a grade for the complete device or a prediction for an individual infant.
Accuracy (%) describes the share of labeled images classified correctly in the dataset used for that task. It is not the probability that a result for one infant is correct.
Intersection over Union (IoU, %) compares the model’s segmented area with the reference annotations. A higher overlap is better for that segmentation task, but does not establish clinical usefulness.
Each number comes from a different model and dataset. They should not be ranked against one another. The source omitted percent signs for the two accuracy values; this page uses the conventional 0–100 percentage scale for readability.
The reported work does not establish external validation, performance in clinical practice, or performance of the integrated device. Important details, including some sample sizes and confidence intervals, were not supplied.
Methods, additional scores and limitations
Stage-related classification
Precision 93.39; recall/sensitivity 92.03; F1 92.32. Classes were Normal, Stages 1–3 and laser scars. Stages 4 and 5 were absent, so these results cannot support safe referral prioritization or deprioritisation.
Plus-disease classification
Precision 88.9; recall/sensitivity 89.8; F1 89.4. Dataset size, patient-level split and confidence intervals were not supplied.
Segmentation
IoU 76.81% using HVDROPDB and U-Net. The supplied record does not document external validation.
Not yet evidenced
The proposed binary ROP route has no supplied benchmark. Zone classification was not trained because the record reports that no suitable public dataset was identified.
The source reports the stage and plus accuracy values without a percent sign. This page displays them using the conventional 0–100 percentage scale for readability; confirm the original analysis record before reusing the figures. These are separate public-dataset development tasks with incomplete evaluation details. They are not directly comparable, externally or clinically validated, or evidence of device-level performance. No specificity, AUROC or confidence intervals are claimed.
Public video of the physical automated-microscopy research prototype.
microscopIA-led engineering · benchtop research prototype
Automated microscopy research for malaria
A physical microscopIA prototype connecting automation, imaging and review by laboratory professionals. Explore the demonstration, the research objective and the validation still needed.
Research use and demonstration limits
The public video documents a physical microscopy prototype. The program investigates automated image acquisition and software-assisted flagging of candidate fields, quality issues or samples for review by trained laboratory professionals. It does not confirm or exclude malaria, establish species or parasite density, choose treatment, or replace laboratory quality assurance and clinical judgement.
Any future application to another microscopy-based tropical disease requires its own intended use, dataset, validation plan and regulatory assessment.
A physical prototype and its public video demonstration. The video documents engineering development; it is not a diagnostic evaluation.
What we investigate
Automated image acquisition and software-assisted flagging of candidate fields or quality issues for review by trained laboratory professionals.
What still needs evidence
Intended-use performance, reproducibility, safety, usability and independent validation with appropriate samples and professionals. These stages are not presented as completed.
What could your team contribute?
Laboratories, malaria experts, engineers and institutions can propose a research scope: reference methods, acquisition evaluation, authorized data, human factors or validation. Responsibilities, resources, ethics, data access and intellectual property are agreed first.
Research priorities start with settings where specialist people and infrastructure are scarce.
02
Human authority
Technology may support acquisition and prioritization; qualified professionals remain responsible for decisions.
03
Evidence before deployment
Safety engineering, usability, governance, training and independent validation precede clinical use.
Collaboration areas: ROP and pediatric ophthalmology, neonatology, optics and imaging, human factors, device engineering, clinical-AI validation, laboratory microscopy, quality systems and regulation.
The work shown here is investigational. Qualified professionals retain clinical decisions. Each system needs evidence appropriate to its intended use, safety assessment and applicable regulatory review before clinical deployment.
Move from an unmet need to a testable specification.
Prepare the conversation
Describe the intended user, care setting, authorized images or samples and the decision the technology should support.
Define the scope
An agreed development scope can include requirements, image acquisition, prototype testing or validation planning. Research prototypes are distinct from clinically authorized devices.